repeat">
Kch India Private Limited
Kch India Private Limited
Thousand Lights, Chennai, Tamil Nadu
GST No. 33AACCK0699L1Z9
08046040294 73% Response Rate
Send E-mail

Cooling Chemicals

Pioneers in the industry, we offer cooling system chemical, liquid oxidizing activator and cooling water treatment chemical from India.
Request CallBack
Cooling System Chemical
Get Best Quote

Cooling System Chemical

Approx. Price: Rs 160 / UnitGet Latest Price
Product Details:
Packaging TypePlastic Can
BrandN/A
Physical StateLiquid
Usage/ApplicationIndustrial
PurityYes
I Deal InNew Only
We are engaged in providing the best quality range of Cooling System Chemical.

Features:

  • AQL 30000 kt- scale, sludge and corrosion inhibitor for cooling towers with stressed water conditions

Benefits:

  • AQL 30000 kt is specially formulated to inhibit the formation of hard water scale and control corrosion of ferrous and nonferrous metals in open re-circulating cooling tower systems. The ingredients in AQL 30000 kt are resistant to chlorine and bromine type bio cides. It will treat water having high hardness or high alkalinity. Contains molybdenum tracer for ease in testing

Description:

  • Featuring a unique multi-polymer formulation that prevents scale formation, AQL 30000 kt also contains dispersants and corrosion inhibitors

Applications:

  • AQL 30000 kt has application in large and medium sized refrigeration type re-circulating cooling systems with extreme hardness and alkalinity
  • Contents (stressed water). This product has application in high-temperature industrial process cooling systems
  • Initial dosage
  • Add sufficient AQL 30000 kt to maintain 2-5 ppm of molybdenum as measured by low-range molybdenum test kit
  • Maintenance dosage: Add sufficient AQL 30000 kt to maintain 2-5 ppm of molybdenum using a low-range molybdenum test kit. Consult your aqua line water treatment consultant for further instructions

Method of feed:

  • AQL 30000 kt can be fed directly into the cooling tower sump or directly into the re-circulating water line using a midstream injection tip. This product should not be mixed with bio cides in a chemical feed solution
  • System operating parameters: Follow the parameters outlined for internal boiler water treatment
  • Refrigeration cooling tower system
  • Cooling water conductivity: 3500 micromhos (max)
  • Total hardness: 900 ppm or
  • Total alkalinity: 600 ppm
  • Silica as sio2 (theoretical): 150 ppm
  • High temperature industrial process
  • Cooling water conductivity: 3500 micromhos (max)
  • Total hardness: 700 ppm or
  • Total alkalinity: 500 ppm
  • Silica as sio2 (theoretical): 150 ppm
  • Product control parameters: add sufficient treatment to maintain 2-5 ppm molybdenum

Physical Properties:

  • Appearance: Amber
  • Ph: 11.8
  • Specific gravity: 1.130
  • Density: 9.43 LBS./GAL

Warning:

  • May cause skin or eye irritation
  • May cause allergic respiratory reaction
  • May cause irritation if inhaled
  • May be harmful if swallowed

Contains the potassium salt of tolyltriazole. Avoid contact with skin, eyes and clothing. Wear neoprene rubber or nitrile gloves, chemical goggles and protective clothing when handling. Wash thoroughly after handling. Keep the container closed when not in use. Avoid breathing the mist. Use sufficient ventilation to prevent a buildup of mist. Swallowing may cause nausea, vomiting and diarrhea.

For eye contact: Immediately rinse the eyes with water. Remove any contact lenses. Hold the eyelids apart to ensure rinsing of the entire surface of the eyes and lids with water. Continue flushing for at least 15 minutes. Get immediate medical attention.

If inhaled: Remove from the area to fresh air. Seek medical attention if respiratory irritation develops or if breathing difficult

Yes! I am Interested
Request CallBack
Liquid Oxidizing Activator
Get Best Quote

Liquid Oxidizing Activator

Approx. Price: Rs 160 / LitreGet Latest Price
Product Details:
Packaging Size5 L
Packaging TypeCan
Brandkch
Grade StandardReagent Grade
Physical StateLiquid
Usage/ApplicationIndustrial
Benefits:
Effective at high ph when used with aql bromact.
Description:
A sodium hypochlorite oxidant, aql chloract acts as the catalyst for aql bromact.
Application / dosage: please consult the aql bromact label for complete directions.
Method of feed: the delivery system must provide through mixing of aql bromact and aql chloract. Aql bromact should be added to the circulation water just before the aql chloract.
Physical properties:
  • Appearance (color) : light yellow green liquid
  • Product ph : 12.4
  • Specific gravity : 1.18
  • Density : 19.2
  • Odor : chlorine.
  • Caution:
  • May cause skin and eye irritation
  • May cause irritation if inhaled
  • May be harmful if swallowed
Benefits:
  • Effective at high ph when used with aql bromact
Description:
A sodium hypochlorite oxidant, aql chloract acts as the catalyst for aql bromact.
Application / dosage: aql chloract used to prevent algae & shellfish growth in cooling towers. In households it is used frequently for the purification and disinfection of the house. It is effective against bacteria, viruses and fungi. It has the advantage that micro organisms cannot buildup any resistance to it. It is effective against legionella bacteria and
Bio film in which legionella bacteria can multiply.
Method of use: use of aql chloract spray and home cleaning to reduce indoor allergen levels and improve asthma health parameters. Preclean all surfaces after use.
Prior to using equipment, thoroughly spray or fog all surfaces until wet, allowing excess
Sanitizer to drain. Vacate area for at least 2 hours.
  • Appearance (color) : light yellow green liquid
  • Product ph : 12.4
  • Specific gravity : 1.18
  • Density : 19.2
  • Odor : chlorine.
Caution:
  • May cause skin and eye irritation
  • May cause irritation if inhaled
  • May be harmful if swallowed
Contains sodium hypo chlorite. Avoid contact with skin, eyes and clothing. Wear neoprene rubber gloves if repeated or prolonged skin contact is likely. Wear safety glasses if the method of application presents the likelihood of eye contact. Avoid breathing the mist. Use sufficient ventilation to prevent the buildup of mist. Wash thoroughly after handling. Swallowing may cause gastrointestinal irritation seen as nausea, vomiting and diarrhea.
First aid:
For skin contact: wash affected areas with plenty of soap and water for several minutes. Seek medical attention if irritation develops. For eye contact: rinse the eyes with water. Remove any contact lenses and continue flushing with plenty of water for several minutes. Seek medical attention if irritation develops.
If inhaled: remove from the area to fresh air. Seek medical attention if respiratory irritation develops, or if breathing becomes difficult.
If swallowed: give 3 to 4 glasses of water, but do not induce vomiting. If vomiting occurs, give fluids again. Seek medical attention if discomfort occurs.
Keep out of the reach of children
Storage: store in a cool, dry place away from heat and direct sunlight to avoid deterioration.
See the material safety data sheet for potential chronic hazards and more information.

Yes! I am Interested
Request CallBack
Cooling System Chemical
Ask For Price

Cooling System Chemical

Product Price : Get Latest Price
Product Details:
Packaging TypePlastic Can
BrandN/A
Physical StateLiquid
Usage/ApplicationIndustrial
PurityYes
I Deal InNew Only
Benefits:

  • Effective at high pH
  • Easy to handle, apply and control
  • Cost effective
  • Much faster kill rates than chlorine
  • Lower corrosion rates than chlorine.
  • Not affected by ammonia.

Description:

AQL Bromact is a liquid, oxidizing biocide specially formulated to control bacteria, algae, fungi and slime in recirculating and once-through cooling water systems, breweries, pasteurizing systems, waste water systems and pulp and paper mills. The EPA registration number is 3377-25-64488. A bromine based biocide, AQL Bromact was developed to overcome the deficiencies of chlorine and chlorine derivatives. It must be used in conjunction with an oxidizing catalyst such as Aqualine AQL Chloract.

Dosage Rates:

Initial Dose: When the system is noticeably fouled, apply sufficient AQL Bromact and AQL Chloract to achieve a residual bromine level of 0.5-1.0 ppm or as needed to maintain control. Typically, the recommended rate is 1.3-5.2 gallon AQL Chloract for each gallon of AQL Bromact.

Method of Feed:


AQL Bromact may be added to the system either continuously or intermittently or as needed, but should be added to the circulation water just before the AQL Chloract. The frequency of feeding and duration of the treatment will depend upon the severity of the problem. It is recommended that the product be used in a manner such that the effluent discharges meet the NPDES guidelines.

Yes! I am Interested
Save time! Get the Best Deal

*Your information is safe with us.

Request CallBack
Cooling Water Treatment Chemical
Get Best Quote

Cooling Water Treatment Chemical

Approx. Price: Rs 160 / kgGet Latest Price
Product Details:
Type Of ChemicalsDisinfectants & Biocides
Usage/ApplicationDesalination
IndustryChemical Processing
Country of OriginMade in India
Brand NameKch
Being a quality-centric organization of this industry, we are engaged in providing a wide array of Cooling Water Treatment Chemical.

Benefits:

  • Provide corrosion protection in the piping of thermal storage units and large closed loops
  • Prevents exchangers and zone valves from plugging due to corrosion
  • Reduces corrosion damage to water pump impellers and seals
  • Non-chromate formula contains no heavy metals

Description:

  • AQL CL 333 is a liquid blend of sodium nitrite, sodium borate, yellow metal inhibitor and a dispersant
  • AQL CL 333 is a non-chromate inhibitor, specially formulated for corrosion in copper, steel and multi-metal systems, whether they are airtight or not

Application:

  • AQL cl 333 is a corrosion inhibitor for use in chilled-water closed loops, hot-water re-circulating boilers and above-ground thermal storage systems. This product provides effective corrosion protection for metals typically found in closed-loop systems. In addition, AQL cl 333 contains a borate buffer to maintain ph of the re-circulating water in the range of 8.5 to 10.5

Product dosage:

  • The initial dosage of AQL cl 333 is 1 liter for each 1000 liters of water in the system (1100 ppm). This will provide a sodium nitrite residual of 275 ppm as nano 2

Method of feed:

  • Feed AQL CL 333 to the closed-loop system using a by-pass pot feeder. For above-ground thermal storage systems, add the product at the time the system is initially charged with water

System operating parameters:

  • Re-circulating water ph: 8.5 to 10
  • Maximum water temperature: 350*f

Product control parameters:

  • Nitrite as nano 2: 225 to 400 ppm
  • Re-circulating water conductivity: 3500 micro ohm or less
  • Re-circulating water ph: 8.5 to 10.5

Physical properties:

  • Appearance: colorless liquid
  • Product ph: 10.8
  • Specific gravity (73*f): 1.21
  • Density: 1.10 kg/l

Note:

Not for use in or for contact with potable water systems or domestic water sources. Not for use in electric steam boilers

Keep from freezing:

  • If this product is stored in cold or freezing temperatures
  • It may separate or thicken
  • This will not harm the performance. Before using, warm to room temperature and stir thoroughly

Warning:

  • Causes skin irritation and allergic skin reaction
  • Causes severe eye irritation
  • May cause irritation if inhaled
  • Harmful if swallowed

First Aid:

For Skin Contact:

Wash affected areas with plenty of soap and water for 15 minutes. Remove contaminated clothing and shoes. Get medical attention. Wash clothing and clean shoes before use. For eye contact: rinse the eyes with water. Remove any contact lenses and continue flushing with plenty of water for 15 minutes. Hold the eyelids apart to ensure rinsing of the entire surface of the eyes and lids with water. Get immediate medical attention. If inhaled: remove from the area to fresh air. Seek medical attention if respiratory irritation develops, or if breathing becomes difficult.

If swallowed:

Immediately give 3 to 4 glasses of water and induce vomiting by placing a finger or blunt object on the back of the victim's tongue. Give fluids until the vomit is clear. Get immediate medical attention. Do not induce vomiting or give anything by mouth to an unconscious or convulsing person.

Yes! I am Interested
X

Reviews & Rating

4.2/5

★★★★★★★★★★

Reviewed by 34 Users

  • 5★59%
  • 4★12%
  • 3★9%
  • 2★6%
  • 1★14%
  • User Satisfaction
  • Response91%
  • Quality     100%
  • Delivery   100%

Most Relevant Reviews

S
★★★★★★★★★★
07-September-22
Sanket A
Mumbai, Maharashtra
Product Name : Water Based Degreaser
Response
Quality
Delivery
S
★★★★★★★★★★
14-August-22
S. Murali
Chennai, Tamil Nadu
Product Name : Degreaser
Response
Quality
Delivery
P
★★★★★★★★★★
04-November-19
Parag Joshi
Guhagar, Maharashtra
Quality will know after few months.
Delivery
View More Reviews