Minimum Order Quantity | 25 Litre |
Usage/Application | Industrial |
Packaging Type | Drum |
Function | Biocides |
Grade Standard | Industrial |
Packaging Size | 25 Liter |
Physical State | Liquid |
Minimum Order Quantity | 25 Litre |
Grade Standard | Industrial Grade |
Packaging Size | 25L |
Usage/Application | Industrial |
Packaging Type | Can |
Physical State | Liquid |
Minimum Order Quantity | 25 Litre |
Packaging Details | 25 kg Bag |
Usage/Application | Food Processing Industry |
Function | Corrosion inhibitors |
Grade Standard | Industrial Grade |
Physical State | Liquid |
Benefits:
*Your information is safe with us.
Minimum Order Quantity | 25 litre |
Usage/Application | Industrial |
Packaging Type | Drum |
Grade Standard | Industrial |
Function | Biocides |
Packaging Size | 25 Liter |
Physical State | Liquid |
Minimum Order Quantity | 25 Litre |
Usage/Application | Industrial |
Packaging Type | Can |
Function | Biocides |
Grade Standard | Industrial |
Packaging Size | 25 Liter |
Physical State | Liquid |
Minimum Order Quantity | 25 Litre |
Packaging Size | 25 Litre |
Packaging Type | Can |
Usage/Application | Industrial Use |
Function | Corrosion inhibitors |
Grade Standard | Industrial Grade |
Physical State | Liquid |
Form | Liquid |
Shelf Life | 1 Year |
Brand | kch |
Country of Origin | Made in India |
BENEFITS: AQL 30000 KT is specially formulated to inhibit the formation of hard water scale and control corrosion of ferrous and nonferrous metals in open recirculating cooling tower systems. The ingredients in AQL 30000 KT are resistant to chlorine and bromine type biocides. It will treat water having high hardness or high alkalinity. Contains molybdenum tracer for ease in testing. DESCRIPTION: Featuring a unique multi-polymer formulation that prevents scale formation, AQL 30000 KT also contains dispersants and corrosion inhibitors. INITIAL DOSAGE: Add sufficient AQL 30000 KT to maintain 2-5ppm of molybdenum as measured by Low-Range Molybdenum Test Kit. MAINTENANCE DOSAGE: Add sufficient AQL 30000 KT to maintain 2-5ppm of molybdenum using a Low-Range Molybdenum Test Kit. Consult your AQUALINE water treatment consultant for further instructions. METHOD OF FEED: AQL 30000 KT can be fed directly into the cooling tower sump or directly into the recirculating water line using a midstream injection tip. This product should not be mixed with biocides in a chemical feed solution. SYSTEM OPERATING PARAMETERS: Follow the parameters outlined for internal boiler water treatment. |
|
*Your information is safe with us.
Minimum Order Quantity | 25 Litre |
Packaging Sizes | 5 Litre |
Type Of Chemicals | Corrosion Inhibitor |
Usage/Application | Industrial |
Form | Liquid |
Physical State | Liquid |
Grade Standard | Technical Grade |
Country of Origin | Made in India |
BENEFITS: AQL 30000 KT is specially formulated to inhibit the formation of hard water scale and control corrosion of ferrous and nonferrous metals in open recirculating cooling tower systems. The ingredients in AQL 30000 KT are resistant to chlorine and bromine type biocides. It will treat water having high hardness or high alkalinity. Contains molybdenum tracer for ease in testing.
DESCRIPTION: Featuring a unique multi-polymer formulation that prevents scale formation, AQL 30000 KT also contains dispersants and corrosion inhibitors.
APPLICATIONS: AQL 30000 KT has application in large and medium sized refrigeration type recirculating cooling systems with extreme hardness and alkalinity
Contents (stressed water). This product has application in high-temperature industrial process cooling systems.
INITIAL DOSAGE: Add sufficient AQL 30000 KT to maintain 2-5ppm of molybdenum as measured by Low-Range Molybdenum Test Kit.
MAINTENANCE DOSAGE: Add sufficient AQL 30000 KT to maintain 2-5ppm of molybdenum using a Low-Range Molybdenum Test Kit. Consult your AQUALINE water treatment consultant for further instructions.
METHOD OF FEED: AQL 30000 KT can be fed directly into the cooling tower sump or directly into the recirculating water line using a midstream injection tip. This product should not be mixed with biocides in a chemical feed solution.
SYSTEM OPERATING PARAMETERS: Follow the parameters outlined for internal boiler water treatment.
REFRIGERATION COOLING TOWER SYSTEM
Cooling water conductivity | : | 3500 micromhos (max) |
Total hardness | : | 900 ppm or |
Total alkalinity | : | 600 ppm |
Silica as SiO2 (Theoretical) | : | 150 ppm |
HIGH TEMPERATURE INDUSTRIAL PROCESS | ||
Cooling water conductivity | : | 3500 micromhos (max) |
Total hardness | : | 700 ppm or |
Total alkalinity | : | 500 ppm |
Silica as SiO2 (Theoretical) | : | 150 ppm |
Packaging Size | 5 L |
Packaging Type | Can |
Brand | kch |
Grade Standard | Reagent Grade |
Physical State | Liquid |
Usage/Application | Industrial |
Minimum Order Quantity | 25 Litre |
Packaging Size | 5 L |
Packaging Type | Can |
Grade Standard | Industrial |
Physical State | Liquid |
Usage/Application | Industrial |
Country of Origin | Made in India |
*Your information is safe with us.
Minimum Order Quantity | 25 Litre |
Grade Standard | Industrial Grade |
Packaging Size | 25L |
Usage/Application | Industrial |
Packaging Type | Can |
Physical State | Liquid |
Packaging Type | Can |
Packaging Size | 10 L |
Usage/Application | Industrial Use |
Form | Liquid |
Brand | kch |
Country of Origin | Made in India |
Usage/Application | Industrial |
Packaging Type | Drum |
Function | Biocides |
Grade Standard | Industrial |
Packaging Size | 25 Liter |
Physical State | Liquid |
Benefits:
*Your information is safe with us.
Grade Standard | Industrial Grade |
Packaging Size | 25L |
Usage/Application | Industrial |
Packaging Type | Can |
Brand | KCH |
Physical State | Liquid |
Model Name/Number | Oxaway Extra |
Packaging Sizes | 10 Litre |
Brand | Kch |
Usage/Application | Industrial |
Physical State | Liquid |
Grade Standard | Technical Grade |
Packaging Type | Bottle |
Form | Liquid |
BENEFITS: AQL 30000 KT is specially formulated to inhibit the formation of hard water scale and control corrosion of ferrous and nonferrous metals in open recirculating cooling tower systems. The ingredients in AQL 30000 KT are resistant to chlorine and bromine type biocides. It will treat water having high hardness or high alkalinity. Contains molybdenum tracer for ease in testing.
DESCRIPTION: Featuring a unique multi-polymer formulation that prevents scale formation, AQL 30000 KT also contains dispersants and corrosion inhibitors.
APPLICATIONS: AQL 30000 KT has application in large and medium sized refrigeration type recirculating cooling systems with extreme hardness and alkalinity
Contents (stressed water). This product has application in high-temperature industrial process cooling systems.
INITIAL DOSAGE: Add sufficient AQL 30000 KT to maintain 2-5ppm of molybdenum as measured by Low-Range Molybdenum Test Kit.
MAINTENANCE DOSAGE: Add sufficient AQL 30000 KT to maintain 2-5ppm of molybdenum using a Low-Range Molybdenum Test Kit. Consult your AQUALINE water treatment consultant for further instructions.
METHOD OF FEED: AQL 30000 KT can be fed directly into the cooling tower sump or directly into the recirculating water line using a midstream injection tip. This product should not be mixed with biocides in a chemical feed solution.
SYSTEM OPERATING PARAMETERS: Follow the parameters outlined for internal boiler water treatment.
REFRIGERATION COOLING TOWER SYSTEM
Cooling water conductivity | : | 3500 micromhos (max) |
Total hardness | : | 900 ppm or |
Total alkalinity | : | 600 ppm |
Silica as SiO2 (Theoretical) | : | 150 ppm |
HIGH TEMPERATURE INDUSTRIAL PROCESS | ||
Cooling water conductivity | : | 3500 micromhos (max) |
Total hardness | : | 700 ppm or |
Total alkalinity | : | 500 ppm |
Silica as SiO2 (Theoretical) | : | 150 ppm |
Minimum Order Quantity | 25 Litre |
Grade Standard | Industrial Grade |
Packaging Size | 25L |
Usage/Application | Industrial |
Packaging Type | Can |
Physical State | Liquid |
*Your information is safe with us.
Minimum Order Quantity | 25 Litre |
Grade Standard | Industrial Grade |
Packaging Size | 25L |
Physical State | Liquid |
Type Of Chemicals | Scale Inhibitor |
Industry | Chemical Processing |
Country of Origin | Made in India |
BENEFITS: AQL 50000 PLUS is specially formulated to inhibit the deposition of silica scale in cooling systems where the silica content of the feedwater is over 25ppm
DESCRIPTION: AQL 50000 PLUS is a primary scale and corrosion inhibitor. It is a liquid blend of phosphoric acid, polymers and a yellow metal corrosion inhibitor.
APPLICATIONS: Use AQL 50000 PLUS whenever the cooling tower feedwater contains 25 or more ppm of silica. The initial dosage in the cooling water is 1 gallon of product for each 2,000 gallons of system capacity. Continue this dosage for 7 days. The maintenance dosage is 1 gallon of product for each 6,000gallons of bleedoff to maintain 10-20ppm phosphonate in the system. .
PRODUCT DOSAGE: Use AQL 50000 PLUS in cooling tower systems when the total ppm of si8lica in the tower water would exceed 150ppm. The initial dosage in the cooling water is 1 gallon of product for each 2000 gallons of system capacity. Maintain this initial concentration (30ppm phosphonate) for 7 days. The maintain dosage is 1gallon of product for each 6000 gallons of bleedoff to maintain 1-20ppm phosphonate in the system.
METHOD OF FEED: AQL 50000 PLUS can be fed directly into the cooling tower sump, or directly into the recirculating waterline, with a midstream injection tip. This product should not be mixed with biocides in chemical feed solutions.
SYSTEM OPERATING PARAMETERS:
Total hardness | : | 700ppm maximum |
Total alkalinity | : | 500ppm maximum |
Silica (theoretical) | : | 300ppm maximum |
Conductivity | : | 3,500 micromhos maximum |
PRODUCT CONTROL PARAMETERS : Phosphonate : 10 to 20 ppm as PO2 |
||
PHYSICAL PROPERTIES: |
||
Appearance | : | Pale yellow |
pH | : | 2.26 |
Specific gravity | : | 1.10 |
Density | : | 8.98 lbs / gallon |
DANGER | ||
CAUSES SKIN AND EYE BURNS |
||
Contains Aminotri (Methylenephosphonic Acid). Do not get in eyes, on skin, or clothing. Wear a face shied, neoprene rubber gloves and protective clothing when handling.Wash thoroughly after handling. Keep the container closed when not in use. Avoid breathing the mist. Use sufficient ventilation to prevent a buildup of mist. Do not swallow. |
Grade Standard | Industrial Grade |
Packaging Size | 25L |
Usage/Application | Industrial |
Packaging Type | Can |
Physical State | Liquid |
Model Name/Number | AQL DF 303 |
When foaming occurs, add AQL DF 303 to the water until the foam is killed. If foam
Reappears, reapply AQL DF 303.
Add 1 gallon of AQL DF 303 per 1,500 to 3,000 gallons of total water capacity.
AQL DF 303 can also be used when descaling cooling towers or boilers and for controlling foam in aerated tanks at sewage treatment plants.
Benefits: